Part Number Hot Search : 
BYD13 BYD13 AX671 MB81EDS 1N1197 8EN1YMBK TM24064B A5800349
Product Description
Full Text Search
 

To Download B88069X0680T502 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Switching spark gap
SSG with lead wires
Series/Type: Ordering code: Version/Date:
CAS02X-068 B88069X0680T502 Issue 05 / 2007-11-22
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or footer when copying the content.
Identification/Classification 1: (header 1 + top left header bar) Identification/Classification 2: (header 2 + bottom left header bar) Ordering code: (top right header bar) Series/Type: (top right header bar) Preliminary data (optional): (if necessary) Department: Date: KB AB E / KB AB PM Issue 05 / 2007-11-22 Switching spark gap SSG with lead wires B88069X0680T502 CAS02X-068
(c) EPCOS AG 2007. Reproduction, publication and dissemination of this document, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Switching spark gap SSG with lead wires
B88069X0680T502 CAS02X-068
Features Extremely long life time Stable performance over life Insensitive performance against variations in temperature Low switching losses Very short breakdown time High reliability by robust design RoHS compatible
Applications Ignition circuits
Electrical specifications DC spark-over voltage 1) 2) Initial values Ignition time tI after 150 hours in darkness 3) at -20 C at +25; 125 C Electrical life time Maximum increase of DC spark-over voltage Switching operations at +25; 125 C Switching frequency 10 ... 25 Hz Switching frequency < 10Hz Test circuit parameters Open circuit voltage V0' Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP Insulation resistance at 100 Vdc Capacitance at 1 MHz Weight Operation and storage temperature Climatic category (IEC 60068-1) Marking, red positive
CS 230 YY MM O
200 ... 255
V
95 4 2 25 2 000 000 4 000 000 230 15 2.2 10 ~ 300 > 0.1 <2 ~ 1.5
99.9 5 3
100 7 4
% s s
V Ignitions Ignitions Vac k F H A G pF g C
-20 ... +125 20/ 125/ 21
CS 230 YYMM O
- Series - Nominal voltage - Year of production - Month of production - Non radioactive
KB AB E / KB AB PM Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 4
Issue 05 / 2007-11-22
Switching spark gap SSG with lead wires
B88069X0680T502 CAS02X-068
1) 2) 3)
At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode, after load Time from capacitor charged to the first high voltage spark Test circuit: Vac = 198 V; R = 36 k; C = 2.2 F
Dimensional drawing
Not to scale Dimensions in mm Non controlled document
Cautions and warnings Switching spark gaps may be used only within their specified values. Damaged switching spark gaps must not be re-used.
KB AB E / KB AB PM Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 4
Issue 05 / 2007-11-22
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 4 of 4


▲Up To Search▲   

 
Price & Availability of B88069X0680T502

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X